filereference:output:buildings [2020/06/24 16:24]
enviadmin
filereference:output:buildings [2020/06/29 12:39] (current)
enviadmin edited the outputs and inserted some descriptions
Line 29: Line 29:
  
 ==== Static ==== ==== Static ====
 +
 +The static dataset includes some information that does not change during the model run. The *.DAT-files contain some statistical information about the specific buildings, such as the surface and volume (Building List.DAT) and the facade orientation,​ element count, element surface, green element count and green surface count (Building Statistics.DAT).
 +
 +The *.EDX/EDT output files contain the following parameters:
 +
 +
 |  |**Variable** |**Unit** |**Description** | |  |**Variable** |**Unit** |**Description** |
-|  |Albedo of facade| - |  +|  |Albedo of facade| - | Albedo of the facade, the proportion of the radiation that is reflected by the facade ​
-|  |Transmission of facade| -  |  +|  |Transmission of facade| -  | Transmission of the facade, fraction of shortwave radiation transmitted through the material ​
-|  |Emissivity of facade | -  |  +|  |Emissivity of facade | -  | Emissivity of the facade, emissivity for longwave thermal radiation ​
-|  |View factor sky | - |  +|  |View factor sky | - | Proportion of sky that can be seen by the facade element ​
-|  |View factor soil | -  |  | +|  |View factor soil | -  | Proportion of soil that can be seen by the facade element ​ | 
-|  |View factor bldg| -  |  | +|  |View factor bldg| -  | Proportion of buildings that can be seen by the facade element ​ | 
-|  |View factor veg| - |  | +|  |View factor veg| - | Proportion of vegetation that can be seen by the facade element ​ | 
-|  |Building number | -  |  +|  |Building number | -  | Building number of building ​
-|  |Facade/ Roof Greening LAI | m³/​m³ ​ | | +|  |Facade/ Roof Greening LAI | m³/​m³ ​ | LAI of Facade/Roof Greening that is applied to the element ​
-|  |Facade/ Roof Greening Thickness | cm  |  |+|  |Facade/ Roof Greening Thickness | cm  | Thickness of Facade/Roof Greening that is applied to the element ​|
  
  
  
 ==== Dynamic ==== ==== Dynamic ====
 +The dynamic dataset includes some information that does change during the model run. It is divided into the different building elements and contains the following parameters. ​
 +
 ===Wall=== ===Wall===
  
 |  |**Variable** |**Unit** |**Description** | |  |**Variable** |**Unit** |**Description** |
-|  |Wall shading flag| - |  +|  |Wall shading flag| - | Information whether your facade element receives direct radiation or not 
-|  |Temperature Node 1/ outside | °C  |  +|  |Temperature Node 1/ outside | °C  | Temperature of the material outside ​
-|  |Temperature Node 2 | °C  |  +|  |Temperature Node 2 | °C  | Temperature of the material at node 2 
-|  |Temperature Node 3 | °C  |  +|  |Temperature Node 3 | °C  | Temperature of the material at node 3 
-|  |Temperature Node 4 | °C   ​| ​ | +|  |Temperature Node 4 | °C   ​| ​Temperature of the material at node 4  | 
-|  |Temperature Node 5 | °C   | | +|  |Temperature Node 5 | °C   ​| ​Temperature of the material at node 5  ​
-|  |Temperature Node 6 | °C   | | +|  |Temperature Node 6 | °C   ​| ​Temperature of the material at node 6  ​
-|  |Temperature Node 7/ inside | °C   ​| ​ +|  |Temperature Node 7/ inside | °C   ​| ​Temperature of the material inside ​
-|  |Longwave radiation emitted by facade | W/m²  | | +|  |Longwave radiation emitted by facade | W/m²  | Amount of longwave radiation that gets emitted by the facade ​
-|  |Wind Speed in front of facade | m/s |  +|  |Wind Speed in front of facade | m/s | Wind speed, vector sum over all 3 axis
-|  |Air Temperature in front of facade| °C |  +|  |Air Temperature in front of facade| °C | Potential air temperature in the atmosphere in front of the facade ​
-|  |Shortwave radiation received at facade | W/m²   ​| ​ +|  |Shortwave radiation received at facade | W/m²   ​| ​Total amount of shortwave radiation received at the facade ​
-|  |Absorbed direct shortwave radiation | W/m²   ​| ​ +|  |Absorbed direct shortwave radiation | W/m²   ​| ​Amount of direct shortwave radiation that gets absorbed by the facade ​
-|  |Incoming longwave radiation | W/m²  |  +|  |Incoming longwave radiation | W/m²  | Amount of longwave radiation that hits the facade ​
-|  |Reflected shortwave radiation facade | W/m²   ​| ​ +|  |Reflected shortwave radiation facade | W/m²   ​| ​Amount of reflected shortwave radiation that hits the facade ​
-|  |Sensible Heat transmission coefficient outside| W/​m²K ​ |  |+|  |Sensible Heat transmission coefficient outside| W/​m²K ​ | Sensible Heat transmission coefficient at the outside of the building ​|